10.
Specifications
Type
l Digital exposure meter for ambient and flash metering
Light-receiving method
l Incident and reflected light metering system
Light-receiving section
l Incident light: Lumisphere, Lumidisc
l Reflected light: Lens (light receiving angle of 40°)
Light receiving element
l Silicon photo diode
Metering systems
0 Ambient light: Shutter speed-priority metering
l
Flash light:
With synchro cord
Without synchro cord
Measuring range
l
Ambient light:
EVO to EV19.9 (at 0.1 EV step)
(IS0 100)
*
Flash:
F1.4 to F90 + 0.9 stop (at 0.1 AV step)
Repeat accuracy
kO.1
EV or less
Calibration constant
l
Incident light metering:
C
=
340 (lumisphere), C
=
250 (lumidisc)
*
Reflected light metering: K = 12.5
Display range
l IS0 (film speed): 3 to 8000 (at
1/3
SV step)
l T (shutter speed):
Ambient light: 60 sec to 1/8000 sec (at 1 TV step)
f/s (frames/sec): 8, 12, 16, 18, 24, 25, 30, 32, 64, 128
Opening angle: 180 degrees
Flash:
1 sec to 1/500 sec (at 1 TV step), and 1/75,1/80,1/90,
1/100
l Aperture:
0.5 to 90.9 (at 0.1 AV step)
*
EV (Exposure Value): -5 to 26.2
Other function
l Out-of-range metering:
“E.u” (underexposure) or “E.0” (overexposure) warning indication
l Battery check
l Auto power-off
Battery used
*
A single type-AA battery (Alkaline or manganese), 1.5V
Operating temperature
l 0°C to +4O°C
range
Storage temperature . -20°C to +60°C
range
Dimensions
l Approx. 63W x 110H x 22D mm
Weight
l Approx. 80 g (without battery)
Standard accessories
l Soft case, strap, lumidisc, soft case for lumidisc, synchro terminal cap,
AA battery