SEKONIC
Zoom Master L-508
Operating Manual
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - SEKONIC

SEKONIC Zoom Master L-508 Operating Manual

Page 2 - Table of Contents

5. Measurement 2-2 Auto-reset cordless flash mode Measurements are made by the meter receiving the light from the flash. This measurement mode is us

Page 3 - 1. Parts Designation

5. Measurement NOTE: • The flash unit may flash when you connect the synchro cord or operate the POWER switch. • When firing a flash to make measur

Page 4 - 3. Before Using

6. Advanced Functions 1. Memory function This meter can store up to three measured values in memory for each measurement mode. (incident light mode

Page 5 - 4. Basic Operation

6. Advanced Functions 4. Turn the main lighting off. Now, point the Lumisphere toward the secondary light source. While the Measuring button 19 is de

Page 6

6. Advanced Functions 5. How to use a reflected luminance (cd/m2) meter 1. Make sure that the Index correction value (see page 24) is canceled 2. Set

Page 7

7. Accessories Mini Light Receptor (Sold separately) • Incident light receiving unit with a compact 12mm diameter light receiving surface. • For

Page 8

8. Technical Data Auto illumination : EV 3 and under DIP switch mode selection ¼”Tripod socket : For placing meter in subject area for cordless flash

Page 9

Congratulations on your purchase of a Sekonic Zoom Master L-508 Exposure Meter. The Zoom Master L-508 is the latest addition to the extensive line o

Page 10 - 5. Measurement

1. Parts Designation 16. Zoom Lens Ring 15. Zoom Lens Protective Glass 14. Memory button 13. Memory Clear button 12. Booster Outlet 11. ISO (mai

Page 11

2.Explanation of the Liquid Crystal Display [1] Measuring Mode Icons Ambient (see page 10) Auto-Reset Cordless Flash (see page 15) Cord Flash (s

Page 12 - 6. Advanced Functions

3. Before Using 4. Replacing battery during measurement or when using the memory function • Always turn the power OFF before replacing batteries. If

Page 13

4. Basic Operation 2. Setting measuring mode • Hold down the Mode set button 10 and turn the Set/change dial 5 to select the desired mode. The mode

Page 14

4. Basic Operation 5. When set for reflected light (spot metering) • This method measures the brightness (luminance) of the light reflected from th

Page 15 - 8. Technical Data

5. Measurement 3. Press the Measuring button 19 to make a measurement. Release the Measuring button to complete the measurement. The measured v

Page 16 - 10. Care and Maintenance

5. Measurement 2. Measuring flash light This method of measurement can be done in the following modes; with cord, without cord, multiple flash with c