4. Turn the main lighting off. Now, point the Lumisphere
toward the secondary light source. While the
Measuring button 19
is depressed and held down,
the indicated difference between the main and
auxiliary light sources is displayed in EV values and
in bars in analog scale of memory value. A lighting
ratio (contrast ratio) can be found in the scale below.
Reference:
• To determine exposure after adjusting lights, turn both main and auxiliary light sources
on, raise the Lumisphere to the UP position, then take a reading along the camera light
4. How to use the L508 as an Incident Illuminance (LUX) meter
1. Turn the Lumisphere UP/DOWN ring 1 to lower it to
3. Set the meter to EV mode (DIP switch) and ISO 100.
4. Place meter parallel to the subject and take a
measurement.
5. Convert the measured EV with a conversion table or
calculation formula to find the brightness level.